renewableenergyforbusinesses

Cutting Business Energy Costs: What to Do First, by Payback

Updated 23 October 2026 · Renewable Energy for Businesses

Want to cut what your site uses and pays for energy?

Request a quote

What should come first, second and third?

Order measures by effort and by how soon the saving shows. GOV.UK's Energy Efficiency for Businesses site groups its measures the same way, from actions that cost very little or nothing to longer-term investments. Few official sources publish a payback for each measure, so the table gives the effort level and the best-sourced figure, and says where none exists.

StepEffortWhat the sources sayCaveat
1. Measure the siteLittle or noneCarbon Trust: measurement and control are key steps. Energy Saving Trust: regular readings or smart meter data give a baselineWithout a baseline no later saving can be shown
2. Check contract, meter and bill linesNo equipmentOfgem: out-of-contract and deemed rates are usually dearerCuts the price per kWh, not the kWh
3. Switch off and controlNo or low costGOV.UK: nearly half of business electricity use falls outside standard operating hoursNeeds routines that stick
4. LED and lighting controlsLow to mediumGOV.UK: payback under 3 years on average. Energy Saving Trust: immediate savings of up to 75%Depends on what is replaced and the hours run
5. Heating settings, draught-proofing, boiler careLowEnergy Saving Trust: space heating is 49% of energy use in a non-domestic buildingWorkplace minimum temperatures apply
6. Voltage checkLow to find outSee the voltage optimisation guideOnly where measured voltage is high
7. Compressed air, motors, refrigerationLow to mediumCarbon Trust (2012): for compressed air, reducing leaks is the single most important measure for most businessesOnly where the process uses them
8. Insulation and heat recoveryMedium to highNo payback figure in the pages checkedGet a site-specific estimate
9. On-site generationCapitalSized last, on the reduced loadSee the last section

Treat every figure as the source's range, not a promise for your site. The Carbon Trust said in 2012 that even low and no-cost actions can usually reduce energy costs by at least 10%, and Energy Saving Trust says SMEs could make savings of up to 30% by making changes around their business.

Why does measuring come before spending?

A saving you cannot see is a saving you cannot prove, and equipment bought for the wrong load wastes money. Energy Saving Trust suggests regular meter readings, or smart meter data, compared with factors such as how many people were in that day. The Carbon Trust describes an energy walk-round to find where waste occurs. A customer can also ask the supplier for up to 12 months of historic smart or advanced meter data. The monitoring guide sets out what to record and what each reading decides. A gas reading can be turned into kWh with the gas meter reading calculator.

What can be fixed on the bill without buying equipment?

  • The contract. Ofgem says some suppliers move a customer onto out-of-contract rates when a fixed term ends without a new deal, and that these are usually more expensive. Some contracts renew automatically for a fixed term, usually 12 months, and may be on a higher rate. Diarise the end date; the contract renewal guide has the detail.
  • Reserved capacity. For sites with a current transformer (CT) meter, Ofgem's guide says the network operator charges for the capacity it has reserved. If the charge looks too high, ask the operator.
  • Reactive power. A CIBSE Journal module from 2012 says a power factor below 0.9 is often penalised through supply tariffs with a charge for reactive power. Look for that line, then see the power factor guide.

A better contract lowers the price per kWh. It does nothing about the number of kWh, so it sits beside the steps below, not in place of them.

What do controls and out-of-hours waste offer?

GOV.UK advises turning off lights in unoccupied areas, switching unused appliances off at the socket, and timing heating and air conditioning around when people are present. It suggests heating offices to 19°C and cooling at 24°C or higher. The Carbon Trust's warehousing guide says low and no cost savings can easily come from better controls and night-time and weekend shut-down routines.

Comfort sets a floor. Energy Saving Trust notes that the Approved Code of Practice suggests a workplace should normally be at least 16°C, or 13°C where the work involves a lot of physical effort. For heating, ventilation and air conditioning, which the Carbon Trust says can account for the majority of what an organisation spends on energy, its guide orders the opportunities from reducing the need, through housekeeping and controls, to maintenance and then hardware. That is a sound order for any site.

Which equipment upgrades come next?

Lighting

GOV.UK says upgrading to LED bulbs could deliver significant savings, on average in under 3 years, and Energy Saving Trust cites immediate savings of up to 75% from efficient lighting. Both depend on what is being replaced and how long the lights run. The LED and controls guide covers specification. Do lighting before voltage work: Business Energy Scotland lists retail sites with LED lighting and efficient appliances already in place among those where voltage optimisation may be less effective.

Compressed air, motors and refrigeration

In its 2012 compressed air guidance the Carbon Trust said the technology accounts for around 10% of UK industry's electricity consumption, that reducing air leaks is the single most important energy saving measure for most businesses, and that reducing pressure by 10% can lead to 5% savings in energy. For motors, Energy Saving Trust lists switching them off during breaks and optimising the speed of equipment, and the variable speed drives guide looks at the latter. On refrigeration, it lists keeping doors closed, defrosting regularly and repairing door seals. The Carbon Trust's refrigeration guide also has a section on heat recovery, though the pages checked give no payback for it.

Heat

Energy Saving Trust says space heating accounts for 49% of energy use in a non-domestic building, and lists draught-proofing and insulating hot water tanks, boilers and pipes. GOV.UK adds that well-maintained boilers are significantly more efficient, and that a lower boiler flow temperature will not noticeably cool the premises but may lengthen warm-up.

How do you compare paybacks and avoid double counting?

  • Ask for the basis. A quoted payback depends on running hours, the unit price and the baseline. Ask each quote to state them, so that proposals can be compared on one footing.
  • Allow for interaction. Measures share the same load. A site that fits LEDs first has less for later measures to act on, so re-measure between steps rather than adding up headline savings.
  • Weigh the length of return. GOV.UK asks businesses to consider the risks and length of return before a longer-term investment.
  • Check the product. GOV.UK points to the Energy Technology List of government-approved energy efficient products.

Where does on-site generation fit?

Last. Every kilowatt-hour removed first is one an array or battery no longer has to cover, so sizing generation on the reduced profile avoids paying for capacity that waste would have used. The energy management page and the small business guide show how the options fit together, and readers can send an enquiry through the form on the energy management page.

Sources and last checked

Checked on 22 October 2026. Several Carbon Trust items date from 2012 to 2019 and are labelled as such, so the official pages are the authority if they disagree with this one.

Guides on this topic

Common questions

How much can a business realistically save?

The sources give ranges, not forecasts. The Carbon Trust said in 2012 that low and no-cost actions can usually cut energy costs by at least 10%, and Energy Saving Trust says SMEs could save up to 30% overall. A site that has already fitted LEDs and sorted its controls will probably find less left to save.

I rent my premises. What can I do?

Energy Saving Trust suggests taking regular meter readings or reading smart meter data, checking that heating controls bring heating on only when and where it is needed, and asking whether the thermostat can be turned down.

Is switching supplier the same as saving energy?

No. A cheaper contract lowers the price you pay per kWh, but the number of kWh stays the same. The two work together, and Ofgem notes that deemed and out-of-contract rates are usually higher than negotiated ones, so the contract is worth checking first.

Which measure has the shortest payback?

No-cost actions such as switching off out-of-hours load pay back at once because nothing is spent. Among purchases, the pages checked publish one average: GOV.UK puts LED upgrades at under 3 years. For anything else, ask the quote to state its assumptions and compare on the same basis.

Request a renewable energy for businesses quote

By submitting you agree to our privacy policy. We never sell your details.

Related guides

Request a quote
Request a quote