Gas Meter Reading to kWh Calculator for Business Gas Bills
Updated 28 October 2026 · Renewable Energy for Businesses
Gas meter reading to kWh
Your gas in kWh
- Units used
- –
- Cubic metres
- –
- Energy
- –
- Therms
- –
- Energy cost
- –
Enter the previous and current readings from the meter or the bill.
Send these detailsThe conversion follows the steps GOV.UK sets out under the Gas (Calculation of Thermal Energy) Regulations 1996. Nothing you enter is stored or sent unless you send it through the form.
Why is gas measured in cubic metres but billed in kWh?
A meter counts volume, but the heat in each cubic metre depends on the gas flowing that day, so the conversion is set in law. GOV.UK guidance says all the conversion factors are prescribed in the Gas (Calculation of Thermal Energy) Regulations 1996, and the bill then prices the result in kWh.
What are the steps from a meter reading to kWh?
- Units used: the current reading minus the previous one.
- Imperial meters only, × 2.83: an imperial unit is 100 cubic feet, and GOV.UK converts a cubic foot at 0.0283 cubic metres. Metric readings skip this step.
- × calorific value: the figure on the bill, in megajoules per cubic metre (MJ/m³).
- × 1.02264: the correction for temperature and pressure, because gas expands and contracts.
- ÷ 3.6: turns megajoules into kWh.
A hypothetical example on an imperial meter: readings of 4,512 and 4,736 give 224 units, or 633.92 cubic metres. At the 39.5 MJ/m³ GOV.UK uses as an example, 633.92 × 39.5 × 1.02264 ÷ 3.6 is about 7,113 kWh.
Reversed, kWh × 3.6 ÷ (calorific value × 1.02264) gives cubic metres: 10,000 kWh at 39.5 MJ/m³ is about 891 cubic metres, or 315 imperial units. For therms, divide kWh by 29.3071, the figure the Gas (Metrication) Regulations 1992 added to the Gas Act 1986 definition of a therm, so 10,000 kWh is about 341 therms.
Is the meter metric or imperial?
GOV.UK says a metric meter registers in cubic metres and an imperial one in cubic feet. Every new meter is metric, but a significant number of imperial meters are still used for billing; if in doubt, ask the supplier. Read either type left to right, ignore any digit shown in red and keep any zeros. Imperial meters often show part units on a dial, and one full turn is one cubic foot.
The wrong type is the costliest slip. An imperial reading treated as metric understates the kWh by about 65%, and a metric reading treated as imperial overstates it 2.83 times.
Where does the calorific value come from?
National Gas says most customers in Great Britain are billed on a daily average for their charging zone, the Flow Weighted Average Calorific Value (FWACV). Xoserve calculates and publishes it on the Gas Data Portal, and its Postcode Exit Zone List shows a site's zone. The figure on a bill is an average of the gas supplied over the billing period.
Regulation 4A, added in 1997, sets each day's value at the lower of the area figure and the lowest input value plus one megajoule per cubic metre. GOV.UK adds that transporters must keep the figure between 38 and 41 MJ/m³, because gas outside that range causes problems for appliances.
| Calorific value (MJ/m³) | kWh per 100 cubic metres | kWh per 100 imperial units |
|---|---|---|
| 38.0 | 1,079 | 3,055 |
| 39.5 | 1,122 | 3,175 |
| 41.0 | 1,165 | 3,296 |
Calculated with the steps above: the same reading varies by about 7.9% across that range.
Does 1.02264 apply to every business meter?
No. Regulation 2 of the 1996 regulations fixes it where gas is reasonably expected not to exceed 732,000 kWh (25,000 therms) a year. Above that, the factor is T × P × Z. P comes from the pressure at the meter, less a deduction for its height above sea level, and Z is one where the metering pressure does not exceed 2 bar. T is a standard temperature factor of 1.0098.
A large site's bill can therefore differ from this method; ask the supplier which factor it uses.
How does the kWh figure turn into a bill?
- Unit rate: the kWh are multiplied by the price per kWh on the bill; the business gas price guide has official averages to compare.
- Standing charge: GOV.UK notes a bill may add one, or use a tiered price.
- Climate Change Levy: HMRC makes the supplier responsible for charging it, at a main gas rate of 0.801p per kWh from 1 April 2026. See the Climate Change Levy guide.
- VAT: standard rate unless the supply qualifies for the reduced rate, on a value that includes the levy and standing charge. See the VAT guide.
A year of converted readings is also the baseline for costing a heating or efficiency project (see the cost guide); readers can send an enquiry through the form.
How do you check an estimated bill?
Take two actual readings, convert the difference and compare it with the kWh billed for the same dates. Ofgem's back-billing rules can mean energy used more than 12 months ago does not have to be paid for, and the back-billing guide explains which businesses they protect. Billing complaints go to the supplier first, GOV.UK says, and the Energy Ombudsman can investigate if the supplier cannot resolve them.
Sources
All checked on 28 October 2026.
- Office for Product Safety and Standards (GOV.UK): Gas meter readings and bill calculation (published 10 June 2014).
- legislation.gov.uk: Gas (Calculation of Thermal Energy) Regulations 1996, regulation 2 and Schedule, and the 1997 Amendment Regulations; Gas (Metrication) Regulations 1992, regulation 3.
- National Gas: Our data and Gas quality.
- HMRC (GOV.UK): Climate Change Levy rates (updated 27 November 2025) and VAT on fuel and power (VAT Notice 701/19) (updated 28 October 2026).
- Ofgem: What to do if you get a back bill.
Guides on this topic
- Business Electricity Cost Calculator: Unit Rate, Standing Charge, Levy and VAT
- Energy Unit Converter: kWh, MWh, Joules, Therms and BTU for Business Energy
Common questions
How many kWh are in one cubic metre of gas?
About 11.2 kWh at the calorific value of 39.5 MJ/m³ that GOV.UK uses as an example: 1 × 39.5 × 1.02264 ÷ 3.6. The answer moves with the calorific value on the bill, from about 10.8 kWh at 38 MJ/m³ to about 11.6 kWh at 41 MJ/m³.
Is a unit of gas the same as a cubic metre?
Only on a metric meter. On an imperial meter a unit is 100 cubic feet, which GOV.UK converts at 2.83 cubic metres, so an imperial unit holds 2.83 times as much gas. Check which type the meter is before converting.
Why might my own sum not match the kWh on my bill?
The bill uses an average calorific value for the whole billing period, so one day's figure will differ slightly. The readings may have been estimated rather than actual. And where a site is expected to use more than 732,000 kWh a year, the correction factor is calculated from the metering pressure and height rather than fixed at 1.02264.
Where can I see the calorific value for my area?
National Gas says calorific value data for each charging zone can be viewed or downloaded from its Gas Data Portal, and Xoserve's Postcode Exit Zone List shows which zone a postcode falls in. For checking a bill, the figure printed on that bill is the one to use.
How many kWh is a therm?
29.3071 kWh, the equivalence the Gas (Metrication) Regulations 1992 added to the Gas Act 1986 definition of a therm. The thermal energy regulations stopped referring to therms on 1 January 2000, so a therm figure is mainly useful for comparing older bills, contracts or records.