Time-of-Use Electricity Tariffs for Business: How They Work and When They Pay
Updated 28 October 2026 · Renewable Energy for Businesses
Want to cut what your site uses and pays for energy?
Request a quoteWhat is a time-of-use tariff for a business?
It is an electricity contract in which the unit rate depends on when the site uses power. As Ofgem puts it, paying the same unit rate throughout the whole day is a single rate tariff, while a multi-rate tariff such as Economy 7 charges one unit rate during peak hours and another off-peak.
Ofgem has explained that lower prices reflect the lower cost of generating and transmitting electricity at certain times: power is cheap when there is lots of wind and solar energy available, and expensive when diesel-powered generators are used.
| Structure | How the rate changes | What you need to judge it |
|---|---|---|
| Two-rate (day and night) | One rate for a set off-peak period, usually overnight, another for the rest of the day | A meter that records both periods |
| Multi-band | Three or more fixed bands, such as peak, shoulder and off-peak | Half-hourly data by weekday, weekend and season |
| Half-hourly | A separate rate for each half-hour, the interval in which electricity is measured and settled | Half-hourly metering and automatic controls |
Ofgem's current call for input on the household price cap says suppliers are incentivised to offer tariffs that pass on price signals, such as lower prices overnight compared to daytime, and reward use outside high-cost periods.
Why is half-hourly settlement making these offers more likely for smaller businesses?
Because a supplier's costs start to depend on when each site uses power. Ofgem says market-wide half-hourly settlement (MHHS) changes how suppliers are settled when buying electricity to match their customers' demand, and Elexon, which runs settlement, says it can base settlement on actual consumption for each half-hour in place of estimates or monthly readings. Ofgem's 2021 decision expected this to give retailers the incentive to develop and offer new tariffs and innovations such as time of use tariffs, automation, vehicle to grid solutions and battery storage.
On 28 October 2026 Elexon reported that every company planning to take part in half-hourly settlement had qualified, meeting the Milestone 14 deadline, with around 75% of meters already migrated. Suppliers have until 7 May 2027 to finish moving meters. The half-hourly settlement guide covers the timetable and data access.
No supplier has to quote a time-of-use rate: Ofgem notes there are several types of business energy contract and that suppliers may not offer all of them. Its guide for businesses gives the practical step: ask potential suppliers about a time-of-use tariff to see if your business can make the most of off-peak deals.
Which parts of a business bill change with the time of day?
Two layers can vary. The energy price is the supplier's rate for each band, and it is what a time-of-use tariff changes. Network charges already vary: Northern Powergrid charges suppliers a daily fixed charge and time of use unit charges. It says small businesses generally do not see these because they sit inside the supplier's bill, while industrial and commercial customers may see them identified.
National Grid Electricity Distribution publishes its network time bands as red, amber and green, in UK clock time, and says the information may help connected customers take advantage of cheaper time bands. A supplier's peak window need not match your network's most expensive band, so check both. The battery storage savings guide shows how the network bands feed into a storage case.
Residual network charges do not change with timing. Ofgem's Targeted Charging Review made them fixed charges for all households and businesses, so leave them out of any saving.
How can you tell whether a time-of-use tariff would pay?
Test the offer against a year of the site's own half-hourly data. The energy monitoring guide covers what else to measure.
- Get the data and the offer. Twelve months of half-hourly use, plus the band times, band rates and standing charges in writing.
- Sort the half-hours into bands. Find the share of annual kWh in the peak band, for weekdays and weekends, winter and summer.
- Run a do-nothing test. Price last year's use on the flat and time-of-use offers with no change in behaviour. If time-of-use already wins, the decision rests on contract terms.
- Find the break-even peak share. Setting standing charges aside, a two-rate offer beats a flat rate when the peak share is below (flat rate minus off-peak rate) divided by (peak rate minus off-peak rate). For example, if the peak rate sits twice as far above the flat rate as the off-peak rate sits below it, break-even is one third of use. Do the same sum band by band for multi-band offers.
- Estimate what can move out of the peak on a typical weekday without harming output, comfort or safety, using the table below.
- Re-price with the shift. Each kWh moved saves roughly the peak to off-peak gap, less the cost of moving it, such as pre-heating losses or overtime.
- Add a storage or controls scenario, then stress-test everything with a colder winter and the least favourable rates the contract allows.
Which loads can a business move out of the peak?
It depends on whether the load can be stored as heat, cold, charge or finished work, so a depot charging a fleet overnight can usually move far more than a shop trading into the evening.
| Load | Ease | How it moves | Watch for |
|---|---|---|---|
| EV charging, vehicles parked overnight | Easy | Scheduled charging after the peak | Vehicles ready for the first shift |
| Water heating with a storage cylinder | Easy | Heat the store off-peak | Enough hot water for the day |
| Space heating by heat pump or electric heaters | Moderate | Pre-heat, using the building's thermal mass | Comfort late in the peak window |
| Cooling and refrigeration | Moderate | Pre-cool; cold stores ride through short peaks | Product temperature limits |
| Batch work: washing, mixing, firing, pumping | Varies | Reschedule to early morning or night | Staffing, noise and deadlines |
| Compressed air | Some | Larger receivers, and fixing leaks | Pressure at the point of use |
| Lighting, IT, tills and catering | Hard | Little beyond efficiency | Tied to opening hours |
What do batteries and smart controls change?
They separate when the site uses power from when it buys it. Ofgem has described how a battery can recharge when electricity is cheap and plentiful, and says energy storage allows businesses to shift their energy use. Charged off-peak and discharged through the peak, a battery makes even the "hard" loads above shiftable. Each stored kWh is worth roughly the peak to off-peak gap less conversion losses, and the battery has to last the whole peak window. The commercial battery storage page covers sizing, uses and connection.
Controls do the same job more cheaply where the load can wait: water heater timers, a building management system that pre-heats or pre-cools, or EV chargers that start after the peak. NESO's Demand Flexibility Service lets homes and businesses be rewarded for shifting when they use electricity, and on 9 April 2026 it added bi-directional flexibility, so some events reward using electricity at a different time. It needs a supplier or aggregator registered for the service and a working smart meter, and each event is optional. The demand side response guide covers it.
What are the risks of a time-of-use tariff?
- Peak exposure. If use cannot move and the peak rate is high, the bill rises.
- A poor fit. A peak band over your busiest hours leaves little to shift. Get band times in writing, including weekends and bank holidays.
- Contract terms. Can the supplier change bands or rates mid-term? Which charges are passed through? What does leaving early cost? The contract renewal guide explains end-of-term rules.
- Data and metering. Ofgem's April 2025 market report said smart meters had been installed in 61% of businesses, so check what your meter records. When larger sites moved to half-hourly reads, Ofgem noted some businesses were asked to pay more because suppliers needed more time and resources to collect and process the data. Ask for metering charges to be itemised.
- Site changes. A new shift pattern, heat pump or EV fleet changes the profile, so re-test the tariff.
Readers who want a site-specific view of whether storage or controls would make an offer pay can send an enquiry through the form on the battery storage page.
Sources
- Ofgem: price cap unit rates page; half-hourly settlement blog (26 July 2017); price cap calls for input (25 March and 12 October 2026); MHHS decision (20 April 2021); P272 and P322 guide (15 June 2021); Get a business energy contract; Targeted Charging Review decision (18 December 2019); retail market report (15 April 2025).
- Elexon: Half hourly settlement; Market-wide Half Hourly Settlement; news of 28 October 2026.
- Northern Powergrid, About us; National Grid Electricity Distribution, Clearview Charge.
- NESO: Demand Flexibility Service pages.
- All checked 28 October 2026.
Guides on this topic
Common questions
Is a day and night tariff a time-of-use tariff?
Yes, the simplest kind. Ofgem describes multi-rate tariffs such as Economy 7 as charging one unit rate during peak hours and another off-peak. Offers with more bands, or half-hourly rates, follow the same idea.
Can a small business get a time-of-use electricity tariff?
It depends on the supplier and the meter. Ofgem expects half-hourly settlement to give suppliers an incentive to offer time-of-use tariffs, but suppliers may not offer every contract type. Ask for one alongside a flat quote at renewal.
Will using more power off-peak reduce the fixed charges on my bill?
No. Ofgem's Targeted Charging Review made residual network charges fixed for all households and businesses, so timing does not change them. Shifting affects the time-banded unit rates and, where the contract passes them through, network time-band charges.
Do I need a battery to benefit from a time-of-use tariff?
No. If heating, cooling, charging or batch work can move out of the peak window, scheduling and controls may be enough. A battery helps where the peak load cannot move, since the site keeps running while drawing less at peak.