renewableenergyforbusinesses

What Is a Heat Network? District and Communal Heating Explained for Businesses

Updated 10 November 2026 · Renewable Energy for Businesses

Weighing up a heat pump or other low-carbon heating?

Request a quote

A heat network swaps a boiler in every building for one energy centre and a set of insulated pipes. Heat travels as hot water, or occasionally steam, to each connected building or unit, and each customer draws what it needs through a connection on site. A business might meet one through an offer to connect, a lease in a block heated from one plant room, a council's zoning plans or its own campus plant. This hub explains the basics and points to the four guides on the rules.

How does a heat network work?

Ofgem lists the parts as pipes, heat interface units, heat exchangers, substations and energy centres. DESNZ's heat network optimisation guide, which follows the terms of CIBSE's CP1 code of practice, explains how they fit together:

  • Energy centre. Plant rooms holding the boilers, combined heat and power (CHP) units or other plant that make the heat, with pumps and thermal stores.
  • Distribution pipes. Mostly buried, pre-insulated pipes to each building. Water goes out on the flow pipe and comes back cooler on the return, and the guide says returns should run at least 20°C below the flow to keep heat losses down.
  • Substation. Usually where a district network meets a building's own pipework, holding valves and heat meters. A direct substation lets network water flow straight into the building; an indirect one separates the two with a plate heat exchanger.
  • Heat interface unit (HIU). The connection in each flat or unit, passing heat to that customer's heating and hot water circuits. The Warm Homes Plan notes it is typically smaller than a gas boiler.
  • Heat meters. They record each building's or customer's use, which billing based on consumption relies on.

Size separates the types. The Warm Homes Plan describes communal networks inside one building, campus networks across one site and district networks across a town, and says most UK networks are communal. The legal definitions and metering duties are in the communal heating guide; the network types Ofgem regulates are in the heat network regulation guide.

Where does the heat come from?

On most existing networks, gas. The government's 2021 national assessment of district heating found natural gas was the primary fuel of existing networks, burnt in boilers or CHP plant, which the CHP guide explains. As the government's December 2018 market framework paper put it, networks are not automatically low-carbon.

Their advantage is reach. The Warm Homes Plan names heat from the ground and watercourses, surplus heat from industry and infrastructure, and high-temperature sources such as geothermal, nuclear and energy from waste. Large heat pumps lift low-grade heat from the ground, rivers or mine water on many newer schemes, and some designs put a smaller unit in each building instead; the commercial heat pump page covers that technology at business scale. Examples:

  • Energy from waste. Leeds PIPES, a Warm Homes Plan case study, heats over 4,000 homes and 29 non-residential buildings by burning non-recyclable waste.
  • Data centres. A north-west London scheme in the plan pairs a data centre with a network to serve 10,000 new homes and 250,000 m² of commercial space.
  • Mine water. The Mining Remediation Authority, formerly the Coal Authority, estimates that 25% of UK homes and businesses sit above former coal mines, where water is typically 10 to 20°C and up to 40°C at around 1 km down. Gateshead has Great Britain's largest mine water heat network.
  • Geothermal. The Cornwall geothermal guide covers the deep projects there.

Lower-temperature networks and shared ground loops. DESNZ's Green Heat Network Fund guidance describes ambient, or fifth-generation, networks running much cooler than traditional ones, typically 20 to 30°C on the flow and around 10°C on the return. That cuts heat losses, opens up low-grade sources and suits heating and cooling, but each building needs its own equipment to raise the temperature. A shared ground loop is similar: Ofgem describes a shared closed ground or water loop with a separate unit for each customer, so most heating costs usually arrive on the electricity bill. DESNZ's January 2026 technical standards consultation calls both designs relatively new and increasingly used.

How does a business buy heat from a network?

Through a contract with the network's heat supplier, often called a heat supply agreement, or through a lease where the landlord supplies heat. Ofgem's fair pricing guidance of 13 January 2026, written for suppliers serving domestic and non-domestic customers, says pricing currently varies, combining connection charges, standing charges, unit rates and other fixed charges:

  • Connection charge. The cost of joining. Ofgem proposes recovering it through the standing charge, as it does not vary with use, and says a connection already paid for, such as by a one-off charge, should not be added to heating bills too.
  • Standing charge. A charge that does not vary with the heat used.
  • Unit rate. The price of each unit of heat the meter records.

Expect a long relationship: the 2018 paper said a network's buildings and pipes can carry heat for up to 60 years, against around 15 for a CHP generator. Before signing, check the term and exit terms, how prices are set and changed, the split between standing charge and unit rate, who maintains the substation, HIUs and meters, and what happens when supply stops.

Ofgem has regulated heat network operators and suppliers in Great Britain since 27 January 2026. Every operator and supplier of a relevant network must register with Ofgem by 26 January 2027, and the regulation guide explains what that means for a business customer, including Ofgem's June 2026 research with businesses on networks.

How common are heat networks in the UK?

Still a small share, but set to grow. The Warm Homes Plan, published by DESNZ on 21 January 2026, says registered networks in England supply around 12.4 TWh of heat, 3% of overall UK heat demand. It expects low-carbon networks to meet around a fifth of heating demand by 2050, with a nearer target of at least 7% of England's heat demand by 2035, more than double today's level.

Business premises are expected to be part of that growth. The plan expects networks to serve a larger share of demand in towns and cities, particularly in public and commercial buildings, and estimates that district networks could best meet over 50% of heat demand in London and Manchester. Most networks today are communal: the 2018 paper counted around 14,000 in the UK, about 2,000 district and 12,000 communal.

What rules apply, and what is changing?

Four sets of rules are moving at once, each with its own guide. Positions as checked on gov.uk, Ofgem's site and legislation.gov.uk on 10 November 2026:

AreaPositionWhereGuide
Ofgem regulationLive from 27 January 2026; operators and suppliers register by 26 January 2027Great BritainHeat network regulation
Technical standards (HNTAS)Not in force; launch planned for 2027, phased inGreat BritainHNTAS explained
Heat network zoningNot in force; first zones prepared ahead of the legislationEnglandHeat network zoning
Metering and billingIn force; partly revoked in Great Britain from 27 January 2026 to avoid duplicating OfgemUK; unchanged in Northern IrelandCommunal heating rules

Scotland

Regulation is devolved: the Heat Networks (Scotland) Act 2021 gave Scotland its own powers, including council-designated zones, while consumer protection on pricing, transparency and service quality is reserved, so Ofgem's regime applies too. The Scottish Government says networks supply just under 2% of Scotland's heat, and the Act's targets rise from 2.6 TWh of heat supplied in 2027 to 6 TWh in 2030 and 7 TWh in 2035.

Northern Ireland

Ofgem regulates in Great Britain only. Northern Ireland keeps the 2014 metering and billing rules, and the Department for the Economy says its existing networks, believed to number about 100 and mainly communal, mostly run on fossil fuels. In August 2026 it consulted on a regime that would make the Utility Regulator the heat network regulator, with authorisation of operators.

What are the advantages and drawbacks for a business?

The Competition and Markets Authority's market study, reported on 23 July 2018, remains the main independent review of the market. It looked at domestic networks, but its findings frame the questions a business should ask:

  • Price can compare well. For many customers, prices were close to or lower than gas or electricity alternatives, with comparable service.
  • Outcomes vary. Some customers on certain privately operated schemes did worse on price and service, and higher unit prices and annual charges went with privately operated and individually metered schemes.
  • Supply is a monopoly. Networks have features of natural monopolies and customers have little or no ability to switch, so the contract carries the weight.
  • Less plant on site. Connected buildings need no boilers of their own, and the Warm Homes Plan notes that upgrading one central heat source is simpler than changing every building.

The CMA called for statutory regulation, which Ofgem now provides in Great Britain. Readers weighing a connection against their own plant can use the enquiry form on this page.

Sources

All pages checked 10 November 2026; the official pages are the authority if they differ.

Common questions

Is communal heating the same as district heating?

Both are heat networks. Communal heating serves separate customers inside one building from its own plant, while district heating pipes heat between separate buildings, sometimes across a town. The difference matters for metering duties and for which rules apply.

Can a heat network provide cooling?

Yes. The Warm Homes Plan says 10% of current heat networks already provide cooling in some form, and DESNZ's Green Heat Network Fund guidance says lower-temperature ambient networks suit both heating and cooling.

Is heat from a network low-carbon?

Only as low-carbon as its source. Natural gas is still the main fuel of existing networks, while newer schemes use sources such as energy from waste, mine water, geothermal and recovered heat. Ask the supplier what the energy centre uses now and what it plans to use.

Who regulates heat networks in Northern Ireland?

Not Ofgem, whose regime covers Great Britain. The 2014 metering and billing regulations still apply there, and the Department for the Economy consulted in August 2026 on making the Utility Regulator the heat network regulator.

Request a renewable energy for businesses quote

By submitting you agree to our privacy policy. We never sell your details.