renewableenergyforbusinesses

Replacing Oil or LPG Heating at a Rural Business: The Options

Updated 23 October 2026 · Renewable Energy for Businesses

Weighing up a heat pump or other low-carbon heating?

Request a quote

A rural business with oil or LPG heating has four realistic routes: a heat pump, a biomass boiler, an electric boiler, or a renewable liquid fuel in the boiler it already has. None wins everywhere. The deciding factors are the building's heat loss, the electricity supply, space for plant or fuel, and how fuel is delivered. This guide compares the routes, sets out the grant conditions in England and Wales, and covers what to do about the tank. The wider range of low-carbon heating is in the renewable heating comparison.

What are the main options for replacing oil or LPG?

OptionSuitsCheck firstSupport or status
Heat pump (air or ground source)Buildings with fabric and heat emitters that work at lower temperatures, and space for the unit or ground loopsElectrical capacity, design temperatures, building fabricBoiler Upgrade Scheme grant in England and Wales; see the commercial heat pump page
Biomass boilerSteady heat demand, room for a fuel store and lorry accessStore size, delivery route, smoke control rulesGrant for rural properties never connected to the gas grid; see the biomass boiler guide
Electric boilerSmall or occasional loads, or no room for a heat pumpElectrical supply and running costNo dedicated grant; see the electric boiler guide
HVO (hydrotreated vegetable oil) in an oil boilerSites keeping the existing boiler and tankThe boiler maker's written position on the fuelTrade body says supply is ready; government outcome awaited
Bio-LPG in an LPG systemSites keeping LPG appliances and tankSupplier availability and blendTrade body says it is a drop-in fuel; government outcome awaited

What does the Boiler Upgrade Scheme pay a rural business?

According to GOV.UK on 22 October 2026, the scheme is open to people in England and Wales, and the grant can be used for a building used for a business. The amounts that matter for oil and LPG sites are:

  • £7,500 towards an air source heat pump, and £7,500 towards a ground source heat pump, including water source pumps and those on shared ground loops.
  • An additional £1,500 towards either type until March 2027, where the property is heated by oil or LPG and has no mains gas connection. Together that is £9,000.
  • £5,000 towards a biomass boiler, which is limited to rural properties never connected to the gas grid.

The conditions to check are that the applicant owns the property, including where it is a business, that the system is replacing fossil fuel heating and not a low-carbon system, that the installer is MCS-certified, and that the system stays within the maximum capacity of 45 kWth, or 70 kWth when installed as a cascade. The scheme is not open in Scotland or Northern Ireland, where the Scotland page and Northern Ireland page cover local support.

Can HVO or bio-LPG replace oil or LPG without changing the boiler?

Their trade bodies say yes, and government has not yet settled the question. OFTEC, which represents the oil heating industry, says that industry is ready to begin supplying the new fuel to existing oil heating customers, starting with a 20% blend of HVO with kerosene, and that no new heating equipment needs to be installed. It also asks the government to align the duty on HVO with kerosene. Liquid Gas UK, the trade association for the LPG and biopropane industry, says bioLPG is chemically identical to LPG and can be dropped in to existing LPG equipment and appliances, and that it is available on the market in the UK today. What HVO is, and how its carbon saving is counted, is set out in the HVO fuel guide.

These are industry statements. On the government side, DESNZ's consultation on the role of alternative clean heating solutions ran from 18 November 2025 to 10 February 2026 and covers domestic and non-domestic buildings. The page says heat pumps and heat networks will work well for the majority of properties, that the department is analysing feedback and that the outcome will be published on the page. Until it appears, treat liquid fuels as a possible bridge rather than a settled long-term route.

Before relying on either fuel, get the boiler or burner maker's written confirmation for the exact model, check that the tank and fittings are compatible, and ask the supplier about the blend share and availability at the site's postcode.

How do running costs compare?

This guide prints no pence-per-kWh league table. No current official series for heating oil, LPG or wood fuel delivered to a business was available to cite on 22 October 2026, and a figure from a trade page or a supplier would not be a like-for-like comparison. The comparison to run is the same for every option: the cost of one kWh of heat.

OptionCost of a kWh of heat isWhere the inputs come from
Oil or LPG boilerFuel price per kWh divided by boiler efficiencyDelivery quote, including minimum drop and delivery charge, and the energy content per litre or kilogram stated by the supplier
Heat pumpElectricity price per kWh divided by seasonal efficiencyThe site's electricity tariff and the designer's seasonal performance estimate
Electric boilerElectricity price per kWh divided by boiler efficiencyThe site's electricity tariff
Biomass boilerDelivered price per tonne divided by energy per tonne, then by boiler efficiencySupplier quotes stating moisture content
HVO or bio-LPGQuoted price per litre or kilogram divided by energy content and efficiencySupplier quote stating the blend

CIBSE says a heat pump's efficiency depends on system design, operating temperatures and building fabric performance, so the efficiency input should come from a design for the building, not from a general figure. Prices move, so repeat the comparison when quotes are about to be signed.

Why start with the building before the fuel?

A replacement sized for a leaky building locks in the waste. A 2012 Carbon Trust article said organisations could make immediate energy savings of 10% through better maintenance and low-cost improvements, such as installing insulation and retrofitting controls, and cut heating costs by up to 30% with simple boiler-related measures. The article is old, so treat those percentages as an illustration of where to look, not a forecast. Reducing heat demand first also lets a smaller, cheaper replacement do the job.

What happens to the oil or LPG tank?

While a business keeps using oil, the storage rules stay in force, and the Environment Agency can say whether they also apply to a tank switched to HVO. GOV.UK says the oil storage rules apply to any container of 201 litres or more at a business, that a bund must hold 110% of the container's capacity, and that the Environment Agency can serve an anti-pollution works notice requiring an oil store to be brought up to legal standards. There are separate requirements for storing agricultural fuel oil on a farm. The GOV.UK guidance does not cover removing a disused tank, so ask the fuel supplier who owns the tank and the Environment Agency what removal involves.

What order should the work go in?

  1. Collect a year of fuel delivery records and convert them to kWh using the supplier's energy content figures.
  2. Fix the cheap losses first: controls, pipework insulation and servicing.
  3. Shortlist options against site constraints: electricity supply, space, lorry access, smoke control status.
  4. Check grant eligibility before signing anything. Ownership, the gas connection history and an MCS-certified installer decide it.
  5. Compare quotes on cost per kWh of heat, using the method above.
  6. Check the tank and fuel store rules for whichever fuel stays on site.

Readers can send an enquiry through the form on this page, and the heat pump page covers the electric route in more detail.

Sources and last checked

Guides on this topic

Common questions

Can a business that rents its premises claim the Boiler Upgrade Scheme?

The applicant must own the property, and GOV.UK includes a business among its examples. A tenant would need to discuss the work with the owner. The conditions are set out on the GOV.UK eligibility page.

Does the extra £1,500 apply to LPG as well as oil?

Yes, on the GOV.UK wording. The property must be heated by oil or LPG and have no mains gas connection, and the extra amount is available until March 2027. It applies to an air source or ground source heat pump.

Does a farm follow the same oil tank rules?

GOV.UK says there are separate requirements for storing agricultural fuel oil on a farm. A farm whose tank serves other business uses should check with the Environment Agency which rules apply.

Does the Boiler Upgrade Scheme apply in Scotland or Northern Ireland?

No. GOV.UK says the scheme is open to people in England and Wales. The Scotland and Northern Ireland location guides cover what applies there.

Request a renewable energy for businesses quote

By submitting you agree to our privacy policy. We never sell your details.

Related guides

Request a quote
Request a quote