Spark spread decides whether burning gas to make your own power beats buying it. With a CHP unit the heat changes the sum, and so do the Climate Change Levy and how many hours the heat is used. This guide works one example through using official 2025 average prices. It illustrates a method; it is not a forecast and not a prediction for any particular unit. The wider picture is on the wind and CHP solution page.

What is spark spread?

Spark spread is the difference between what a unit of electricity is worth and the cost of the gas needed to make it. Gas is priced per kWh of fuel and a generator turns only part of that fuel into electricity, so the gas cost of one kWh of power is the gas price divided by the electrical efficiency. At 35% electrical efficiency a unit burns 1 ÷ 0.35 = 2.86 kWh of gas for every kWh of electricity.

The spread then has to cover everything else: maintenance, the capital cost and any tax. A positive spread is necessary but not enough. The term is also used loosely for the ratio of the electricity price to the gas price, which the business gas price guide covers. For a CHP decision the difference in pence per kWh generated is more useful, because it can be set against maintenance and finance costs.

Which prices go into the sum?

The Department for Energy Security and Net Zero (DESNZ) publishes "Average electricity and gas prices for non-domestic users (nominal terms, across all size bands), including Climate Change Levy". Its annual report shows 24.3p per kWh for electricity and 5.3p per kWh for gas in 2025 (provisional), against 26.3p and 5.7p in 2024, 27.2p and 6.4p in 2023 and 20.9p and 5.3p in 2022. Those swings are why a model has to be re-run when contracts renew.

InputValue usedBasis
Electricity avoided24.3p per kWhDESNZ 2025 (provisional) average, all size bands, including CCL
Gas bought, with CCL5.3p per kWhDESNZ 2025 (provisional) average, all size bands
CCL on gas, 20250.775p per kWhHMRC main rate (0.00775 pounds per kWh)
Gas bought by a CCL-exempt CHP4.525p per kWh5.3p less 0.775p, illustrative
Reference boiler efficiency81%The figure HMRC uses to work out fuel attributable to electricity

Treat the averages with care. They cover every size band, and DESNZ notes that energy prices change depending on consumption levels. The 24.3p is also a delivered price: Ofgem says business prices cover wholesale, network and environmental costs, with wholesale typically about 40% of an electricity bill, and a generator may not avoid all of the rest. The business electricity price guide shows where each part sits.

What does a worked example look like at 2025 average prices?

This is an illustration with assumed unit figures, not a quote. The unit turns 35% of its fuel into electricity and 45% into useful heat, which is consistent with gov.uk saying CHP typically has an efficiency of over 80% and with the NNFCC range for biogas engines of 35-40% to electricity and 40-45% to heat. The real figures come from the unit's datasheet and its CHPQA assessment. Heat is valued as the gas a boiler would have burned, using HMRC's 81% reference boiler efficiency. Everything is per 100 kWh of gas burned, in pence.

CaseElectricity creditedHeat creditedGas boughtMarginMargin per kWh generated
A. Power only, all 24.3p avoided850.500452.50398.0011.37p
B. Power and all heat used850.50294.44452.50692.4419.78p
C. Power and half the heat used850.50147.22452.50545.2215.58p
D. Power only, half the price avoided (12.15p)425.250452.50-27.25-0.78p
E. Power and all heat, half the price avoided425.25294.44452.50267.197.63p
F. As B, but no CCL exemption850.50294.44530.00614.9417.57p

The "half the price avoided" cases are placeholders to show sensitivity, not a measured share. Two break-even figures follow. With no heat used, the electricity price the unit avoids has to exceed 452.5 ÷ 35 = 12.9p per kWh to cover the gas. With all the heat used, the gas attributed to each kWh of electricity falls to (452.5 - 294.44) ÷ 35 = 4.5p. In this example the share of the electricity price actually avoided moves the margin most (425.25p per 100 kWh of gas between cases B and E), the heat credit comes next (294.44p between cases A and B) and the levy least (77.5p between cases B and F).

How do CCL and Carbon Price Support change the result?

HMRC's main CCL rate for gas is 0.775p per kWh in 2025, 0.801p from 1 April 2026 and 0.827p from 1 April 2027. A certified CHP buys its fuel relieved of the levy, which is the 77.5p gap between cases B and F per 100 kWh of gas at the 2025 rate. Full relief depends on CHPQA certification and a power efficiency of at least 20%; the CHPQA guide covers the process and the deadlines.

Carbon Price Support is smaller still. HMRC's notice says a CHP station with a generating capacity of 2 MW or below does not account for it. Above 2 MW it applies to fuel used for non-qualifying electricity, and HMRC's rates page lists 0.331p per kWh of gas, or 33.1p per 100 kWh, from 1 April 2016 to 31 March 2028.

What else decides whether gas CHP still pays?

  • Running hours. The table assumes the unit runs and the heat is wanted. Hours when the heat has nowhere to go behave like case A or D.
  • Maintenance. gov.uk notes that some CHP plants have not met expectations through a lack of effective supervision and maintenance. Turn the maintenance contract into pence per kWh generated and deduct it from the margin.
  • Capital. gov.uk says capital costs are high and payback periods can be long. The finance guide says the annual cost savings must be sufficient to meet the owners' required return on the capital invested.
  • Price moves. Re-run the cases when the gas or electricity contract changes, using your bills, not averages.

How do you run the numbers for a site?

  1. Collect a year of half-hourly electricity and gas data and find the hours when heat is wanted.
  2. Take the unit's electrical and heat efficiencies from the datasheet, at full and part load.
  3. Split your electricity bill into energy and other charges and estimate the share a generator avoids.
  4. Fill in the cases above with your own prices, crediting only heat that is actually used.
  5. Deduct maintenance and capital recovery, each in pence per kWh generated.
  6. Repeat with less heat use and a lower electricity price. If the case works only in the best row, it is fragile.

The micro CHP guide applies this to small units, and a reader can send an enquiry through the site's form to explore a project.

Sources and last checked

Every source below was checked on 22 October 2026. All arithmetic on this page is illustrative and is shown so it can be repeated.

Common questions

Does gas CHP save money if its heat is not used?

It can, but only if most of the electricity price is genuinely avoided. In the illustration the electricity alone covered the gas when all 24.3p was avoided (case A), but fell short when only half was (case D). Heat that has nowhere to go leaves the unit dependent on the electricity price alone.

Is gas CHP affected by Carbon Price Support?

Usually not at business scale. HMRC says a CHP station with a generating capacity of 2 MW or below does not need to register or account for the CPS rates of CCL. Above 2 MW, fuel for heat and for qualifying electricity used on site is left out of the charge.

Which efficiency figures should I use for my own sum?

Use the unit's datasheet at full and part load, then the figures from its CHPQA assessment once it has run. The 35% and 45% in this guide are placeholders chosen to sit inside the ranges gov.uk and NNFCC publish, not a specification.

Request a renewable energy for businesses quote

By submitting you agree to our privacy policy. We never sell your details.

Related guides

Request a quote
Request a quote